HydroTap Arc for Home

HydroTap Arc for Home

01034217_Arc BCS Bright Chrome

Able to complement any kitchen, from traditional to contemporary, the HydroTap Arc has been created with the design enthusiast in mind. With seven exquisite finish options to compliment a range of remarkable functions the HydroTap Arc is the ultimate wellness accessory and a striking kitchen design accessory.

Please use the expandable menu below to view full product specifications.

Arc BCS Tap Specifications:

  • Style: HydroTap Arc – includes child safety lock
  • Hole Size: (35mm) 1-3/8″
  • Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Nickel, Brushed Nickel & Gunmetal
  • Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
  • Flow Rate Max: 1.8 gpm / 6.81 lpm
  • Sparkling Water Flow Rate: 0.4 gpm / 1.51 lpm

120V BCS Command Center Specifications:

  • Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
  • Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
  • Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
  • Water Supply Requirements: Potable drinking water supply
  • Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
  • Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
  • Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
  • Dimensions (WxDxH): 13.3” x 18.2” x 13.1” / 339mm x 462mm x 333mm
  • Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
  • Minimum Cabinet Size: 18” wide x 24” deep / 457mm wide x 610mm deep
  • Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
  • Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
  • Dry Weight: 75lbs / 34kg
  • Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1023, ASSE 1087; cUL; CEC
  • Warranty: 2 years
  • Compatible CO2 Cylinder: Zip Water 1.5lb CO2 or 5lb CO2 (if space allows) with CGA-320 fitting
  • CO2 Operating Pressure: Min 39psi – Max 44psi / Min 2.74 – Max 3.09kg/cm2
Download Specifications

Arc BC Tap Specifications:

  • Style: HydroTap Arc – includes child safety lock
  • Hole Size: (35mm) 1-3/8″
  • Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Nickel, Brushed Nickel & Gunmetal
  • Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
  • Flow Rate Max: 1.8 gpm / 6.81 lpm

120V BC Command Center Specifications:

  • Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
  • Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
  • Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
  • Water Supply Requirements: Potable drinking water supply
  • Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
  • Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
  • Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
  • Dimensions (WxDxH): 18” wide x 24” deep / 457mm wide x 609mm deep
  • Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
  • Minimum Cabinet Size: 18” wide x 24” deep / 457mm wide x 610mm deep
  • Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
  • Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
  • Dry Weight: 66lbs / 30kg
  • Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1023, ASSE 1087; cUL; CEC
  • Warranty: 2 years
Download Specifications

Arc CS Tap Specifications:

  • Style: HydroTap Arc
  • Hole Size:  1-3/8″ (35mm)
  • Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Nickel, Brushed Nickel & Gunmetal
  • Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
  • Flow Rate Max: 1.8 gpm / 6.81 lpm

120V CS Command Center Specifications:

  • Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
  • Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
  • Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
  • Water Supply Requirements: Potable drinking water supply
  • Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
  • Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
  • Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
  • Dimensions (WxDxH): 11” x 16” x 13.1” / 280mm x 406mm x 333mm
  • Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
  • Minimum Cabinet Size: 18” wide x 15” deep / 457.2mm wide x 381mm deep
  • Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
  • Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
  • Dry Weight: 66lbs / 30kg
  • Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1087; cUL; CEC
  • Warranty: 2 years
Download Specifications

Request Quote