The Classic Plus pairs iconic design with intuitive touchpad technology, making it the perfect complement to any kitchen or wet bar. The HydroTap Classic Plus is available in six premium finishes and can be installed over the sink as a secondary tap or on either our integrated or raised font / drip tray.
HydroTap Classic Plus for Home

Please use the expandable menu below to view full product specifications.
HydroTap Classic Plus BCS Tap Specifications:
- Style: HydroTap Classic Plus – includes child safety lock
- Hole Size: (35mm) 1-3/8″
- Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Brushed Nickel, Gunmetal
- Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
- Flow Rate Max: 1.8 gpm / 6.81 lpm
- Sparkling Water Flow Rate: 0.4 gpm / 1.51 lpm
120V BCS Command Center Specifications:
- Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
- Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
- Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
- Water Supply Requirements: Potable drinking water supply
- Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
- Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
- Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
- Dimensions (WxDxH): 13.3” x 18.2” x 13.1” / 339mm x 462mm x 333mm
- Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
- Minimum Cabinet Size: 18” wide x 24” deep / 457mm wide x 610mm deep
- Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
- Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
- Dry Weight: 75lbs / 34kg
- Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1023, ASSE 1087; cUL; CEC
- Warranty: 2 years
- Compatible CO2 Cylinder: Zip Water 1.5lb CO2 or 5lb CO2 (if space allows) with CGA-320 fitting
- CO2 Operating Pressure: Min 39psi – Max 44psi / Min 2.74 – Max 3.09kg/cm2
HydroTap Classic Plus BC Tap Specifications:
- Style: HydroTap Classic Plus – includes child safety lock
- Hole Size: (35mm) 1-3/8″
- Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Brushed Nickel, Gunmetal
- Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
- Flow Rate Max: 1.8 gpm / 6.81 lpm
120V BC Command Center Specifications:
- Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
- Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
- Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
- Water Supply Requirements: Potable drinking water supply
- Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
- Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
- Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
- Dimensions (WxDxH): 18” wide x 24” deep / 457mm wide x 609mm deep
- Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
- Minimum Cabinet Size: 18” wide x 24” deep / 457mm wide x 610mm deep
- Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
- Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
- Dry Weight: 66lbs / 30kg
- Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1023, ASSE 1087; cUL; CEC
- Warranty: 2 years
HydroTap Classic Plus CS Tap Specifications:
- Style: HydroTap Classic Plus
- Hole Size: 1-3/8″ (35mm)
- Available Finishes: Chrome, Brushed Chrome, Matte Black, Brushed Gold, Brushed Nickel, Gunmetal
- Installation: Over Sink or On Drip Tray (Optional Font – see accessories)
- Flow Rate Max: 1.8 gpm / 6.81 lpm
120V CS Command Center Specifications:
- Water Pressure: Min 37psi – Max 100psi (2.60 – 7.03kg/cm2 ) with a minimum flow rate of 1 gpm (3.79lpm)
- Water Connection: ½” BSP – isolation valve is required within 3’ (0.9m) of the installation
- Integral Water Values: All HydroTap systems are fitted with a Dual Check Valve and a 73psi (5.13kg/cm2) Pressure Limiting Valve
- Water Supply Requirements: Potable drinking water supply
- Optimal Total Dissolved Solids (TDS) Range: TDS Min 50ppm – Max 150ppm
- Integral Water Filter: 0.2 micron, 1 size – replace every 1,100 gallons / 4,163 liters or 12 months
- Power Rating: 110-120V, 50-60Hz, 15 amp power supply with a NEMA 5-15 outlet
- Dimensions (WxDxH): 11” x 16” x 13.1” / 280mm x 406mm x 333mm
- Minimum Air Gap: Minimum of 2” / 50mm clearance on left and right side and 8” / 200mm above
- Minimum Cabinet Size: 18” wide x 15” deep / 457.2mm wide x 381mm deep
- Maximum Hose Connection Length: 3’ / 0.9m (tap to command center)
- Minimum Distance Needed for Installation: 15” / 381mm (interior wall to garbage disposal)
- Dry Weight: 66lbs / 30kg
- Product Approvals: IAPMO – NSF/ANSI 372, 42, 53, CSA B483.1, ASSE 1087; cUL; CEC
- Warranty: 2 years